Welcome to the Fluke 117 Instruction Manual, your comprehensive guide to understanding and operating the Fluke 117 Digital Multimeter. This manual provides detailed insights into the device’s features, safe usage practices, and troubleshooting tips to ensure optimal performance. Designed for professionals, the Fluke 117 is a true-rms multimeter ideal for electrical measurements in various settings. It features advanced functions like non-contact voltage detection, capacitance, and frequency testing. By following this manual, users can unlock the full potential of the Fluke 117 while maintaining safety and accuracy in their work.

1.1 Overview of the Fluke 117 Multimeter

The Fluke 117 is a high-performance, true-rms digital multimeter designed for professional electricians. It measures voltage, current, resistance, capacitance, and frequency with precision. Featuring a 6000-count display, it offers accurate readings for various electrical tasks. The multimeter is lightweight, handheld, and built for durability, making it ideal for field use. It supports non-contact voltage detection, ensuring safety, and is compatible with optional accessories like test leads and clamps. With a CAT III 600V safety rating, the Fluke 117 is suitable for industrial and commercial applications, providing reliable performance in demanding environments.

1.2 Importance of the Instruction Manual for Safe and Effective Use

The instruction manual is essential for the safe and effective use of the Fluke 117 multimeter. It provides critical safety precautions, operational guidelines, and troubleshooting tips to ensure accurate measurements and prevent potential hazards. By following the manual, users can understand the device’s capabilities, proper measurement techniques, and maintenance requirements. It also highlights safety standards, such as CAT III 600V rating, to protect users during electrical testing. Adhering to the manual’s instructions ensures optimal performance, reduces risks, and extends the lifespan of the multimeter, making it a vital resource for professionals relying on the Fluke 117 for precise and reliable results.

Safety Information and Precautions

Always follow safety guidelines when using the Fluke 117 to avoid injury or damage. Adhere to CAT III safety standards, and never measure voltages exceeding 600V. Use proper test leads and ensure all warnings are heeded to ensure safe operation and accurate results.

2.1 General Safety Guidelines for Using the Fluke 117

Always use the Fluke 117 as specified in this manual to ensure safe and effective operation. The multimeter is designed for use in Category III (CAT III) environments up to 600V. Avoid measuring voltages exceeding this limit to prevent damage or injury. Never use damaged test leads or accessories, as they can compromise safety. Keep the device away from hazardous conditions, such as explosive atmospheres. Regularly inspect the multimeter and its components for damage. Follow all warning labels and symbols, which indicate potential hazards. Understanding these guidelines is crucial for protecting both the user and the equipment. Safety should always be the top priority when working with electrical measurement tools;

  • Use only Fluke-approved accessories.
  • Avoid exposing the device to extreme temperatures or humidity.
  • Keep the multimeter out of reach of children.

By adhering to these guidelines, users can ensure a safe and reliable measuring experience with the Fluke 117.

2.2 Understanding Warning Labels and Symbols

The Fluke 117 features warning labels and symbols to alert users of potential hazards. An XW warning indicates risks of bodily harm or death, while a WC caution highlights equipment damage risks. Symbols like A (voltalert mode), B (continuity), C (diode test), D (negative input), and E (unsafe voltage) provide quick visual guidance. Always refer to these labels to ensure safe operation. For detailed explanations, consult the manual or visit the Fluke support website. Recognizing these indicators is essential for preventing accidents and maintaining equipment integrity.

  • A: VoltAlert non-contact voltage detection active.
  • B: Continuity testing mode engaged.

2.3 Safe Measurement Practices to Avoid Injury or Damage

To ensure safe operation of the Fluke 117, adhere to these practices: Always use the multimeter within its CAT III 600V rating. Avoid measuring voltages above the specified range. Never touch bare conductors or live circuits with your hands. Use the correct test leads and avoid damaged or worn-out accessories. Before measuring, ensure the multimeter is set to the correct function to prevent incorrect readings. Use the VoltAlert feature to detect voltage without direct contact. Keep the multimeter away from extreme temperatures and moisture. Regularly inspect the device and leads for damage. Follow these guidelines to prevent injury and maintain accurate measurements.

  • Always use the multimeter within its CAT III 600V rating.
  • Avoid measuring voltages above the specified range.
  • Never touch bare conductors or live circuits with your hands.
  • Use the correct test leads and avoid damaged or worn-out accessories.
  • Before measuring, ensure the multimeter is set to the correct function to prevent incorrect readings.
  • Use the VoltAlert feature to detect voltage without direct contact.
  • Keep the multimeter away from extreme temperatures and moisture.
  • Regularly inspect the device and leads for damage.
  • Follow these guidelines to prevent injury and maintain accurate measurements.

Product Features and Specifications

The Fluke 117 is a true-rms multimeter with a 6000-count display, measuring voltage, current, resistance, capacitance, and frequency. It features non-contact voltage detection, CAT III 600V safety rating, and advanced functions like diode testing. Compact and durable, it is designed for professional use in various electrical environments, ensuring accurate and reliable measurements. Its robust design and user-friendly interface make it an essential tool for electricians and technicians. The multimeter also supports optional accessories for enhanced functionality, catering to diverse industrial needs.

3.1 Key Features of the Fluke 117 Digital Multimeter

The Fluke 117 Digital Multimeter offers a range of advanced features designed to meet the demands of professional electricians. It includes true-rms measurement for accurate AC voltage and current readings, a large 6000-count LCD display for clear visibility, and a CAT III 600V safety rating for protection in hazardous environments. The multimeter also features non-contact voltage detection with the VoltAlert function, automatic ranging for convenience, and a battery saver mode to extend usage. Additional capabilities include diode testing, capacitance measurement, and frequency testing, making it a versatile tool for diagnosing and maintaining electrical systems efficiently.

The Fluke 117 Digital Multimeter is designed to deliver precise measurements with a CAT III 600V safety rating. It offers a wide range of measurement capabilities, including AC/DC voltage (0.1mV to 600V), current (0.1mA to 10A), and resistance (0.1Ω to 40MΩ). The multimeter also measures capacitance (1nF to 10,000μF) and frequency (1Hz to 100kHz). With a high-resolution 6000-count display, it provides accurate readings. The device supports true-rms measurements for accurate AC signals and features a response time of 4 digits per second. These specifications make it suitable for diverse electrical applications, ensuring reliability and precision in professional settings.

3.3 Optional Accessories and Compatible Equipment

3.2 Technical Specifications and Measurement Ranges

The Fluke 117 Digital Multimeter is designed to deliver precise measurements with a CAT III 600V safety rating. It offers a wide range of measurement capabilities, including AC/DC voltage (0.1mV to 600V), current (0.1mA to 10A), and resistance (0.1Ω to 40MΩ). The multimeter also measures capacitance (1nF to 10,000μF) and frequency (1Hz to 100kHz). With a high-resolution 6000-count display, it provides accurate readings. The device supports true-rms measurements for accurate AC signals and features a response time of 4 digits per second. These specifications make it suitable for diverse electrical applications, ensuring reliability and precision in professional settings.

Operating the Fluke 117 Multimeter

Learn to navigate the Fluke 117’s intuitive interface and utilize its advanced features for precise measurements. This section covers basic to complex functions, ensuring efficient operation.

4.1 Getting Started: Initial Setup and Battery Installation

Begin by installing the batteries in the Fluke 117, ensuring they are properly seated and the compartment is securely closed. Power on the device to verify it turns on. Familiarize yourself with the controls and display. For accurate measurements, calibrate the multimeter if necessary. Always use the correct battery type as specified in the manual. Refer to the safety guidelines for handling batteries and electrical components. Once powered up, the multimeter is ready for basic operation. Follow the setup instructions carefully to ensure optimal performance and accuracy in your measurements.

4.2 Basic Measurement Modes: Voltage, Current, and Resistance

The Fluke 117 offers three primary measurement modes: voltage, current, and resistance; For voltage measurements, select the appropriate range using the rotary dial and connect the test leads to the input terminals. Current measurements require selecting the correct current range and connecting the leads in series with the circuit. Resistance measurements are taken with the device in ohms mode, ensuring no voltage is present in the circuit. Always use the correct lead placement and range selection for accurate results. The multimeter features auto-ranging for convenience, but manual range selection is also available for precision. Follow safety guidelines to avoid electrical hazards during measurements.

4.3 Advanced Functions: Capacitance, Frequency, and Diode Test

Beyond basic measurements, the Fluke 117 offers advanced functions for capacitance, frequency, and diode testing. Capacitance mode allows users to measure capacitor values, essential for identifying faulty components. Frequency measurement is ideal for testing signal sources and ensuring proper waveform generation. The diode test function checks forward and reverse bias, helping to identify faulty diodes. These advanced modes enhance troubleshooting capabilities in complex electrical circuits. Use the rotary dial to select the desired mode and follow on-screen prompts for accurate readings. These features make the Fluke 117 a versatile tool for diagnosing a wide range of electrical issues efficiently and accurately.

4.4 Using the VoltAlert Non-Contact Voltage Detection Feature

The VoltAlert feature on the Fluke 117 enables non-contact voltage detection, enhancing safety for electricians. When the feature is active, the multimeter emits an audible beep and flashes an LED light if voltage is detected near the tip of the test lead. This function is particularly useful for quickly identifying live circuits without direct contact. To activate VoltAlert, press and hold the dedicated button. The feature automatically deactivates when the multimeter is powered off or when another function is selected. Always ensure the feature is active when working with unknown or potentially live circuits to maintain safety and efficiency in your workflow.

4.5 Understanding the Display and Navigation Controls

The Fluke 117 features a clear, 6000-count LCD display that shows measurements, modes, and warning indicators. Symbols on the display indicate active functions like voltage (V), current (A), resistance (Ω), capacitance (F), and frequency (Hz). Navigation controls include buttons for mode selection, range adjustment, and function activation. The dial allows quick selection between voltage, current, resistance, and other measurement modes. The display also shows warning signs for overload (OL) or unsafe voltage levels. Understanding these elements ensures accurate and efficient operation, enabling users to navigate through measurements and settings intuitively. Familiarizing yourself with the display and controls is essential for optimal use of the multimeter.

Troubleshooting and Maintenance

This section covers identifying common issues, error messages, and performing routine maintenance. It provides steps to reset the multimeter, clean the device, and ensure optimal functionality. Regular checks and proper care extend the lifespan of the Fluke 117, ensuring accurate measurements and reliable performance over time.

5.1 Common Issues and Error Messages

This section addresses frequently encountered issues with the Fluke 117, such as error messages like “OL” (overload) or “NC” (open circuit). It explains how to resolve these by adjusting measurement ranges or checking connections. Additionally, it covers warning messages like “Unsafe Voltage” and negative input indicators. Troubleshooting steps include verifying test lead condition, ensuring proper function selection, and addressing battery-related issues. Guidance is also provided for interpreting and clearing error codes, ensuring accurate measurements and maintaining device reliability. Regular maintenance tips are included to prevent common problems and extend the multimeter’s lifespan.

5.2 Resetting the Multimeter to Factory Settings

Resetting the Fluke 117 to factory settings restores default configurations, useful for resolving software issues or starting fresh. Power on the device, navigate to the settings menu using the navigation controls, and select “Factory Reset.” Confirm the action to erase all custom settings. The multimeter will restart with original factory configurations. Note that this process does not affect measurement accuracy but resets user preferences. For detailed steps, refer to the user manual or contact Fluke support for assistance. This ensures the device operates optimally after the reset.

5.3 Cleaning and Maintaining the Device for Optimal Performance

To maintain the Fluke 117’s performance, regular cleaning and proper handling are essential. Turn off the device before cleaning and use a soft, dry cloth to wipe the exterior. For stubborn marks, a slightly damp cloth may be used, but avoid moisture ingress. Never use harsh chemicals or abrasive cleaners, as they can damage the finish or harm internal components. Store the multimeter in a dry, cool place away from direct sunlight and extreme temperatures. Use the provided case to protect it from dust and physical damage. Regularly inspect and replace the battery if necessary, ensuring terminals remain clean and free from corrosion. For calibration, refer to the user manual or contact Fluke support for professional assistance. Additionally, check for firmware updates to enhance functionality and performance. If issues persist, consult the troubleshooting section or contact customer support for further guidance. Proper maintenance ensures accurate and reliable measurements over time.

Technical Support and Resources

Fluke offers extensive support resources, including online manuals, FAQs, and contact information for assistance. Visit www.fluke.com/support for downloads, troubleshooting, and warranty details. Contact Fluke via phone or email for professional help.

6.1 Contacting Fluke Customer Support

For assistance with the Fluke 117, contact customer support via phone or email. In the USA, call 1-888-99-FLUKE (1-888-993-5853), and in Canada, dial 1-800-36-FLUKE (1-800-363-5853). For Europe, reach out at 31 402-675-200. Visit the official Fluke website at www.fluke.com/support for additional resources, including FAQs, manuals, and troubleshooting guides. Fluke also offers a limited warranty for defective products, ensuring reliable service and repair options. Users can access detailed support information and download materials directly from the Fluke website, making it easy to resolve issues or find answers to common questions.

6.2 Accessing Online Resources and Downloads

Visit the official Fluke website at www.fluke.com/support to access a wide range of online resources for the Fluke 117. Download the latest PDF manuals, datasheets, and software updates directly from the site. Explore troubleshooting guides, FAQs, and user forums to resolve common issues. The website also offers detailed technical specifications, measurement guides, and instructional videos to enhance your understanding of the multimeter. Additionally, you can find compatible accessories and optional equipment to optimize your Fluke 117 experience. Regularly updated content ensures you stay informed about the latest features and improvements.

6.3 Warranty Information and Repair Options

The Fluke 117 is backed by a 3-year limited warranty covering defects in material and workmanship. For warranty claims, contact Fluke Customer Support at 1-888-99-FLUKE or visit www.fluke.com/support. Repairs must be performed by authorized Fluke service centers to maintain warranty validity. Before sending your device for repair, register your product online to ensure prompt service. Optional extended warranties may also be available. For international users, refer to regional Fluke websites for specific warranty terms and repair procedures in your area. Always use genuine Fluke parts to avoid voiding the warranty.